Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: transistor; - NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors K2CM-1LS Manual
K2CM-1LS
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mmProduct: Straight Bar Nozzle; 400 mm K2CM-1LS Manual.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Time specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K2CM-1LS Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation OMRON Digital Temperature Controllers Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON Digital Temperature Controllers Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Measuring current: 0 OMRON Digital Temperature Controllers Manual. 1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Supply voltage: 200-230 VAC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay. K2CM-1LS Communications Manual.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and coommercial CT input,
(0 to 1 A or 0 to 5 A) supported K2CM-1LS Manual.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.