LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON K2CM-Q2MAV Manual K2CM-Q2MAV Communications Manual

OMRON K2CM-Q2MAV Manual K2CM-Q2MAV Communications Manual

Product model: K2CM-Q2MAV
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 0.29MB
Control supply voltage: 110/220 VAC; With voltage fluctuation compensation.
Operating current: 0.5 to 1 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K2CM-Q2MAV Communications Manual.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K2CM-Q2MAV
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K2CM-Q2MAV Communications Manual. Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages and undervoltages for three-phase,
3-wire or 4-wire power supplies.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire,
power supply K2CM-Q2MAV Communications Manual.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and,
undervoltages.
World-wide power specifications supported by one Unit,
(switchable using DIP switch).
Relay status can be monitored using LED indicator. Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90-95-100V (9 shunt).
Time hopping: timing; 0.1-0.2-0.4-0.6-0.8-1.0-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: and input common.
Rated consumption VA:7VA.
Control output: 1C, 1A closed 110V 15A1000 L/R=0ms times (DC);
Open 110V 1A DC 1000 (L/R=25ms).
Display: display resolution 1V (display range: 50-130V).
Automatic experiment: there.
Quality: about 1kg.
External: Mount Searl N1.5.
Digital voltage relay series.
K2VU-H/K2VA-H type, large range off adjustment shunt,
Easy to coordinate digital VR K2CM-Q2MAV Manual.
And the automatic tester with convenient for relay testing.
Measurable voltage value.
The reliability can be improved by monitoring the function at any time.
The forced action of tthe experimental switch can be easily recognized K2CM-Q2MAV Manual.
Exterior dimension based on DIN standard,
The depth is only the size of the 88.5mm (terminal except).
Related products
OMRON
Motor Protective Relay
K2CM-2M
OMRON Motor Protective Relay K2CM-2M
Time specification: Inverse type. Current set
OMRON
Motor Protective Relay
K2CM-2HAV
OMRON Motor Protective Relay K2CM-2HAV
Time specification: Inverse type. Current set
OMRON
Motor Protective Relay
K2CM-Q2HA
OMRON Motor Protective Relay K2CM-Q2HA
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-1LS
OMRON Motor Protective Relay K2CM-1LS
Time specification: Inverse type. Current set