File size: 0.29MB
Input type: DC current input.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K2CM-Q4MA Communications Manual.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K2CM-Q4MA
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviPower supply voltage: 100 to 240 VAC K2CM-Q4MA Communications Manual.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods K2CM-Q4MA Communications Manual.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Lineup includes a 17.5-mm slim, compact model.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON.
Supports phase loss detection when the motor is operating.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors. Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automaticallly resetting supported by one Relay K2CM-Q4MA Manual.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input ssupported K2CM-Q4MA Manual.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Related products
OMRON
Motor Protective Relay
K2CM-Q2MV
OMRON Motor Protective Relay K2CM-Q2MV
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
KK2CM-1LA
OMRON Motor Protective Relay KK2CM-1LA
Time specification: Inverse type. Current set
OMRON
Motor Protective Relay
K2CM-Q4MA
OMRON Motor Protective Relay K2CM-Q4MA
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-4H
OMRON Motor Protective Relay K2CM-4H
Time specification: Inverse type. Current set