LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON K3HB-HTA-1 Manual K3HB-HTA-1 Communications Manual

OMRON K3HB-HTA-1 Manual K3HB-HTA-1 Communications Manual

Product model: K3HB-HTA-1
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 2.07MB
Type of input: AC voltage input.
Output type: transistor; -; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth K3HB-HTA-1 Communications Manual.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-HTA-1
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNetMeasuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC K3HB-HTA-1 Communications Manual.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed K3HB-HTA-1 Communications Manual.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Setting range: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the bburned element even if one heater el,
ement among several heater elements has been burned out K3HB-HTA-1 Manual.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K3HB-HTA-1 Manual.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.
Related products
OMRON
Time interval table
K3HB-PPB-ABCD1 AC/DC24V
OMRON Time interval table K3HB-PPB-ABCD1 AC/DC24V
Input type: PNP input type. Event input term
OMRON
Time interval table
K3HB-PNB-FLK1AT11 AC100-240
OMRON Time interval table K3HB-PNB-FLK1AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Load sensor, mV instrument
K3HB-VLC-CPEC21 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-CPEC21 AC100-240
Category: external supply 100mA DC5V type. I