Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-SSD Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K3HB-SSD
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-SSD Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Measuring current: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for current monitoring for,
industrial facilities and equipment K3HB-SSD Manual.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed OMRON Digital Temperature Controllers Manual.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported OMRON Digital Temperature Controllers Manual.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Setting range: 10 to 100 A AC, 20 to 200 A AC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously OMRON Digital Temperature Controllers Manual.
Separate settings and outputs supported for overcurrents and undercurrennts K3HB-SSD Communications Manual.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SSPDT output contacts, 5 A at 250 VAC (resistive load) K3HB-SSD Manual.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.