Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 120-125-130-135-140-145-150V (7 shunt).
Time hopping: timing; -0.2-0.4-0.6-0.8-1.0
-1.2-1.4-1.6-1 K3HB-XAA-1 Manual. 8-2.0s (11 shunt).
Control power supply: No, and input common; there, DC operation
K3HB-XAA-1
Rating consumption VA: No, 6VA (input side);
Have, 2VA (input side) 10W (control power supply side).
Control: 1C, 1A AC110V 7.5Acos output with =0.4
(max 250V 825VA AC);
24V 5A L/R=7ms DC (max 125V 50W when DC).
Display: start display (LED display),
Action display (trip) manual reset.
Automatic experiment: -.
Quality: about 2kg K3HB-XAA-1 Manual.
External: Mount Searl N1.5.
Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work through high reliability semiconductor circuits.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within the hidden from the start to the 2S timer, can easily adjust the time K3HB-XAA-1 Manual.
The control power of the relay is not needed, which avoids the trouble of wiring. Product: Flexible Tube Nozzle; 300 mm.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance OMRON Digital Temperature Controllers Manual. Product: Straight Bar Nozzle; 100 mm.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations OMRON Digital Temperature Controllers Manual.
High-frequency AC method with excellent ion balance. Time specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) OMRON Digital Temperature Controllers Manual.
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicatted from the start of operation K3HB-XAA-1 Communications Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XAA-1 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.