OMRON K3HB-VLC Manual K3HB-VLC Communications Manual

Product model: K3HB-VLC
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 1.84MB
Input type: DC voltage input type.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K3HB-VLC Communications Manual.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-VLC
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNType of input: AC current input K3HB-VLC Communications Manual.
Output type: BCD+ transistor; -; NPN open collector (5 bit output +HH, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-VLC Communications Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DTime specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indiccated from the start of operation K3HB-VLC Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Up/Down Counting Pulse Indicator
K3HB-C Series
OMRON Up/Down Counting Pulse Indicator K3HB-C Series
Measure High-speed Up/down Pulses with this.
OMRON
Voltage and current panel meter
K3HB-XAD-CPAC21 AC100-240
OMRON Voltage and current panel meter K3HB-XAD-CPAC21 AC100-240
Input type: DC current input. Output type: r
OMRON
Time interval table
K3HB-PNB-ABCD1 AC/DC24V
OMRON Time interval table K3HB-PNB-ABCD1 AC/DC24V
Input type: NPN/ voltage pulse input type. E