Control voltage: 100/110/120 VAC.
Reset: Manual.
Model: Inverse type.
Solid-state Relay Provides Three Operating.
Functions in a Compact Package.
Prevents burnouts in 3-phase induction motors due to overcurrent,
open-phase, or reverse-phase.
LEDs indicate operation of the selected operating function S8VM-05015 Connection Guide.
Wide setting ranges: current: 1 to 160 A; operating time: 1 to 40 s
S8VM-05015
Protects the motor from reversing without starting it.
before using the K2CM. Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 150W.
Output voltage: 5V.
Output current: 27A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device S8VM-05015 Connection Guide.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage S8VM-05015 Connection Guide.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Terminal/mounting: Plug-in/DIN rail via socket.
Control voltage: 100/110 VDC.
Under current detection: Instantaneous type.
Solid-state, Plug-in Current Sensor.
Applicable to motor overcurrent protection and 3-phase AC current detection.
Inverse-type, start-up lock type, and instantaneous type over,
current sensors available.
Instantaneous type under current sensor available.
Plug-in design simplifies installation, removal, and wiring.
DIN sized (48 mm x 96 mm). Specifications: Connector with DC line connected(For parallel operation).
Number of Connectors: 10 Connectors (See note 4.).
Block-type Switch Mode Power Supply That.
Mounts to DIN Rail.
One model covers 30 to 120 W (12-V models).
One model covers 60 to 240 W (24-V models).
Easy creation of multi-power supply configgurations with different,
output power supplies connected together (5-V, 12-V, and 24-Vmodels) S8VM-05015 Manual.
Improve power supply system reliability by creating N+1 redun,
dant systems (12-V and 24-V models).
RoHS-compliant.
Input conditioons: 80 to 370 VDC supported for DC input too,
(EC Directives and safety standards are not applicable S8VM-05015 Manual. )
Operating temperatures to –20°C (24-V models).