Box protection class: plastic, IP00.
Terminal size: M4.
Line diameter: 1.25 square mm, 2 square mm.
Weight: 0.7kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Function name: single phase 200V 3G3MX2-AB015-V1 Manual.
Power: 0.75KW.
Maximum output voltage: three phase 200 ~ 240VAC (corresponding input voltage)
3G3MX2-AB015-V1
Rated voltage, frequency: single phase power supply 200 ~ 50/60Hz, 240V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show.
Standard configuration has RS485 interface, Modbus bus communication function 3G3MX2-AB015-V1 Manual.
3Hz provides more than 150% torque output.
2-15kHz carrier frequency, can achieve mute driver.
Equipped with simple energy saving function.
Compact size and uniform, and can be installed close to the side by side.
Signal output function for controlling external brake action.
Software setting operation mode, no need to connect the control line can be used for speed control 3G3MX2-AB015-V1 Manual. Specification: three phase 200V.
Power: 110KW.
Maximum output voltage: three phase AC200 ~ 240V (input voltage correspondence).
Rated voltage: three phase 240V ~ 50/60Hz AC200.
Weight: about 150kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive OMRON 3G3MX2-AB015-V1 EtherCAT Connection Guide.
The high functional specifications are concentrated in the compact OMRON 3G3MX2-AB015-V1 EtherCAT Connection Guide.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function OMRON 3G3MX2-AB015-V1 EtherCAT Connection Guide.
Colorful function.
Brake transistor built-in.
Protection function. Box protection class: plastic, IP00.
Terminal size: M5.
Line diameter: 8 square mm.
Weight: 1.4kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequencyy converter to the power line 3G3MX2-AB015-V1 (RS-485 Modbus Communication).
Try to be close to the transducer for connection. Frequency converter input power: 3 phase AC400V.
Weight: 3.6KG.
Standard applicable line diameter: 8 square mm or more.
Used to suppress harmonicc currents generated by a transducer 3G3MX2-AB015-V1 Manual.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor.