LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> Programmable Terminals CJ1W-PH41U Installation Guide OMRON CJ1W-PH41U Manual

Programmable Terminals CJ1W-PH41U Installation Guide OMRON CJ1W-PH41U Manual

Product model: CJ1W-PH41U
Name: Programmable Terminals
Brand: OMRON
Sort: Installation Guide
File language: English
File size: 4.57MB
For 8-slot Backplane.Model : CVM1D-DPL01.
Simplex system also required.Number of outputs: 16 pts.
Input Voltage: 250 VAC, 24 VAC.
Max Switching Current: 2 Amps.
Common Type: Shared.Model : CV500-CIF21.
When connected to form C500-NC222.Name: High-speed Counter Module.
Model: C200H-CT021.
Number of axes: 2 axis/Unit CJ1W-PH41U Installation Guide.
Operating modes: 7.

High-speed Counter Unit
A High-speed Counter Unit counts input signals from incremental rotary encoders or other sources CJ1W-PH41UModel: C200H-MD501.
No. of I/O pts: 16 inputs, 16 outputs.
Specifications: 5 VDC.CPU Unit: CP1L-L CPU Units with 10 Point.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Relay output;
Inputs, 6; Output, 4 CJ1W-PH41U Installation Guide.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams CJ1W-PH41U Installation Guide. Name: Connector.
Model: C200H-CE002.Power supply: DC power supply.
Output method: Relay output.
Inputs points: 18 points.
Outputs points: 12 points OMRON CJ1W-PH41U Manual. The unit comes with coaxial type.Specification: Platinum resistance thermometer input (Pt100, JPt100),
manual operation,
ON/OFF or advanced PID control,
transistor (NPN) output, 4 loops OMRON CJ1W-PH41U Manual. Specification: 32 output points.Model: C200H-CN711.
Cable length: 70cm.Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: Set separately for each input.
Signal range; Resolution: 1 to 5 V (1/10,000),
0 to 10 V (1/20,000), -5 to 5 V (1/20,000),
-10 to 10 V (1/40,000), and 4 to 20 mA (1/10,000) OMRON CJ1W-PH41U Manual.
Conversion period: 20 μs/1 point, 25 μs/2 points,
30 μs/3 points, 35 μs/4 points,
The Direct conversion is provided.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.4% of F.S.
External connection: Reemovable terminal block CJ1W-PH41U .
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.52A; 24V, --.
Standards: UC1, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analoog Input Units for converting analog input,
signals into binary data CJ1W-PH41U Installation Guide.
Analog Output Units for converting binary ,
data into analog output signals.

Related products
OMRON
CJ-series Input Units
CJ1W-ID233
OMRON CJ-series Input Units CJ1W-ID233
Unit type: CJ1 Basic I/O Units. Product nam
OMRON
Mixed I/O Units
CJ1W-MD Series
OMRON Mixed I/O Units CJ1W-MD Series
A Wide Range of Basic Mixed, I/O Units for D
OMRON
I/O Control Unit / I/O Interface Unit
CJ1W-IC101
OMRON I/O Control Unit / I/O Interface Unit CJ1W-IC101
Product name: CJ-series I/O Control Unit. Sp