I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
Analog setting: YES.Supply voltage: 24V DC.
Output capacity: DC5V, 6.5A.Product name: CJ1M CPU Units; built-in I/O.
Specifications: I/O capacity/Mountable Units Expansion Racks),
160 points/10 Units (No Expansion Rack); Program capacity,
5K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0 CPM1A-30CDR-A-V1 STARTUP GUIDE MANUAL
CPM1A-30CDR-A-V1 1 μs;
Built-in I/O , 10 inputs and6 outputs,
2 counter inputs, 2 pulse outputs.
Current consumption: 5v, 0.64A (Seenote 1.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry CPM1A-30CDR-A-V1 STARTUP GUIDE MANUAL. Product name: CJ1M CPU Units; Without built-in I/O.
Specifications: I/O capacity/Mountable Units Expansion Racks),
640 points/20 Units(1 Expansion Racks max.) ; Program capacity,
20K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0.1 μs.
Current consumption: 5v, 0.58A (Seenote 1.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry CPM1A-30CDR-A-V1 STARTUP GUIDE MANUAL. Name: SYSMAC LINK Module.
Model: C200HW-SLK13.
Communications method: N: N token bus.
Transmission method: Manchester code, base band.
Transmission path: Daisy chain OMRON CPM1A-30CDR-A-V1 Manual.
Weight: 500g max.Name: Clamp Terminal Blocks.
Specifications: Outputs; 8 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON CPM1A-30CDR-A-V1 Manual.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON CPM1A-30CDR-A-V1 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Analog I/O Slave Units,
(Numerical indicator type)
e-CON Connector Type.
Specifications: Analog outputs; 2 outputs.
Standards: CE.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bitt-level I/O distribution reduces,
wiring in the system CPM1A-30CDR-A-V1 .
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CPM1A-30CDR-A-V1 STARTUP GUIDE MANUAL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.