Max input / output points: 10 points.
Supply voltage: 100 - 240VAC.
Input points: 6 points.
Output points: 4 points.
Output type: Transistor (source).
Power consumption (W): 6.
Weight (kg):0.22.
Size (WxHxD) mm:60x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types FR-F820-038000-2-60.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain FR-F820-03800-2-60.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FR-F820-03800-2-60.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication. Protocol: SLMP, TCP/IP, UDP, SNTP.
Communication mode: full duplex / half duplex.
At the same time can open a few: 4 connection.
Weight: 0 MITSUBISHI FR-F820-03800-2-60.3kg.
Can be low cost will be connected to the FX3 series Ethernet.
Support data monitoring, can monitor the basic unit through the computer browser,
Remote maintenance can be carried out by Works2 GX in a place far from the scene.
Connect FX3SA, FX3S, FX3GA, FX3G, FX3U host, you need to convert the adapter or function expansion board MITSUBISHI FR-F820-03800-2-60.
MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 75kw.
SLD converter rated current: 380A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel MITSUBISHI FR-F820-03800-2-60. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on.
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units.
Through the use of wind, temperature and other familiar units can be simple tto maintain and adjust the display FR-F820-03800-2-60. Voltage level: three phase 400V.
Applicable motor capacity: 400kw.
Substrate coating: have.
Built in DC reactor.
The operating frequency of the fixed alternating current is converted to DC power.