Series Name: hand held F940GOT.
System screen display language: english.
Display: 5.7 inches, can operate in the palm of the GOT.
Display color: monochrome.
Display device: LCD STN.
Resolution: 320 * 240.
Installation type: panel mounting.
The built-in communication port: RS-422 (1ch) FX1S-14MT-D.
Power supply voltage: DC24V.
GOOT-F900 series can be easily applied to a variety of different applications.
3 built-in communication channels.
Screen area.
Through the split screen configuration, you can reduce the operating time FX1S-14MT-D.
The image can be divided into two or three parts to display.
According to the user''s application example, the menu screen or the operation of the button sometimes on the screen will often be used to.
As a result, it is very time-consuming and inefficient to make a similar picture every time FX1S-14MT-D. Connecting cable for handheld GOT and PLC.
Cable length: 3 meters.
Application: RS-422 connection.
Max input / output points: 14 points.
Power supply voltage: DC24V.
Input points: 8 points.
Output points: 6 points MITSUBISHI FX1S-14MT-D.
Output type: Transistor (source).
Power consumption (W): 19.
Weight (kg):0.3.
Size (WxHxD) mm:60x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control MITSUBISHI FX1S-14MT-D.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device MITSUBISHI FX1S-14MT-D.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 630KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, thee current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor FX1S-14MT-D.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity.