The type of the drive lever: one way action roller rocker type (horizontal action).
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC) OMRON .
Forced open action structure
S8EX-N03015
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V) OMRON .
Shell color: black.
Control output 1: current output .
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: output (using control output) OMRON .
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade .
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Independent type, the function of the built-in controller is not RS-232C, the maximum 256 points.Name: MIL Connectors.
Specifications: Inputs/Outputs;
16 inputs/16 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiriing material cost can be reduced OMRON S8EX-N03015.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee . OMRON S8EX-N03015.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
S8EX-N03015 Operation manual/Instructions/Model selection sample download link: