LK Automation Limited
Home >> Price >> OMRON >> WS02-CXPC1-CS-V5.0 OMRON WS02-CXPC1-CS-V5.0
Brand sort

WS02-CXPC1-CS-V5.0 OMRON WS02-CXPC1-CS-V5.0

No PHOTO
Country: JAPAN
Name:
Market price: U.S.$ 0
(The following are the market open price not sales price!)
OMRON WS02-CXPC1-CS-V5.0
Output: SPDT.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry OMRON WS02-CXPC1-CS-V5.0.
Detachable Switch.
The same contacts can be used for both standard loads and microloads WS02-CXPC1-CS-V5.0
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 100/110 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white OMRON WS02-CXPC1-CS-V5.0.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement OMRON WS02-CXPC1-CS-V5.0.
Certified for EN 60947-5-1. Output: SPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2 .
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated frrom the start of operation WS02-CXPC1-CS-V5.0.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions WS02-CXPC1-CS-V5.0. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
WS02-CXPC1-CS-V5.0 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=WS02-CXPC1-CS-V5.0&select=5


...more relevant model market price >>>>
Related products
Related download