Sensing distance: (See note 2.)0 to 3.5 mm(pressed position) (See note 1.).
Sensing method: Pushbutton.
Operation mode: ON with no load.
Cable length: 1 m.
Model: NPN output .
Using a pushbutton enables,
accurately detecting difficult-to-detec objects.
Conforms to standards for semiconductor FOUP cassettes to ena,
accurately detecting FOUP cassettes without being affected by the,
material, color, or reflectance of the bottoms of the cassettes
K8AK-AS3 100-240VAC
Thin design enables mounting in a wider range of applications, e.g.,
on transfer arms.
Increased visibility with 4-direction indicator.
Optical detection of actuator operation provides a long life,
(mechanical life: 5 million operations min OMRON K8AK-AS3 100-240VAC. ).
Models available with PNP or NPN output.
Models are available with very flexible robot cable. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Center roller lever.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed OMRON K8AK-AS3 100-240VAC.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models . )
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Appearance: Knob-type Selector Switch A22W,
LED lighting (without Voltage Reduction Unit).
Number of notches: 3 notches.
Resetting method: Manual.
Output: SPST-NO.
Operating voltage: 12 VAC/VDC.
Illumination color: R (red); Y (yellow); G (green); AA (blue) .
Install in 222-dia K8AK-AS3 100-240VAC. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounttedd using either open-type (fork-type) or closed-type,
(round-type) crimp terminals K8AK-AS3 100-240VAC.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
K8AK-AS3 100-240VAC Operation manual/Instructions/Model selection sample download link: