Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- OMRON LAB1 DC5.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance
LAB1 DC5 Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0 OMRON LAB1 DC5. 5%),
Analog input: ±0.2% FS (previous models: ±0 . 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter OMRON LAB1 DC5.
Switch the PV display between three colors .
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Appearance: Unshielded.
Sensing surface: Front.
Sensing distance: 2.5 mm.
Model: Operation mode, NC.
Advanced Performance and Wide.
Range of Selections in a Super.
compact Size.
Only 5.5 × 5.5 mm with a built-in Amplifier.
Maximum sensing distance: 2.5 mm. Stable detection even with,
workpiece fluctuations.
Response frequency: 1 kHz.
Low current consumption. Control power supply voltage: 200/220 VAC.
Input: DC or AC (selectable), Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using currennt converter LAB1 DC5.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrsee current detection LAB1 DC5.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
LAB1 DC5 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=LAB1 DC5&select=5