Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON GRT1-END.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
GRT1-END
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction OMRON GRT1-END.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions . Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Isolation: Photocoupler.
Zero cross function: --.
Indicator: Yes.
Rated output load: 2 A at 5 to 110 VDC OMRON GRT1-END.
Rated input voltage: 200/220 VAC .
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Size: 48 x 96mm.
Type: thermocouple type.
Adjustment mode: ON/OFF action or PID action.
Alarm: single alarm.
Output: relay output.
Temperature controller with single alarm output.
SV and PV can be displayed at the same time.
Multiple temperature range allows setting the optimum temperature range.
The protection function can prevent the error in operation. Appearance: Round/Projection type LED lighting,
(without Voltage Reduction Unit)A22L-T.
Output: SPST-NO + SPST-NC.
Lighting: LED.
Operating voltage: 6 VAC/VDC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting andd removing the Switch Unit GRT1-END.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounteed using either open-type (fork-type) or closed-type GRT1-END.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
GRT1-END Operation manual/Instructions/Model selection sample download link: