Name: MIL Connectors.
Specifications: Inputs;
16 inputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON H2A AC110 10S.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site
H2A AC110 10S
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Terminal type: Exposed-lead Models OMRON H2A AC110 10S.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 15 cm .
Lead wire type: Heat resistive.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON H2A AC110 10S. Output: DPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Number of beams: 64.
Protective height: 1280mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions .
Series connection is possible only with the MSF4800A H2A AC110 10S.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt CCurtain functions H2A AC110 10S.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
H2A AC110 10S Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=H2A AC110 10S&select=5