Appearance: Shielded, M18.
Sensing distance: 5 mm.
Output: NPN.
Model: Operation mode NO.
Aluminum and Iron Both.
Detectable from Long Distances. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black OMRON H2A AC110 30S.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 1 points
H2A AC110 30S
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / OMRON H2A AC110 30S.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay OMRON H2A AC110 30S.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Contact type: Microload (125 VAC, 0.1 A; 30 VDC 0.1 A).
Operation: Momentary operation (Self-resetting).
Output: DPDT.
Lighting: Incandescent lamp, 28 VAC/VDC.
Operation Unit color symbol: Enter the desired color symbol for the Pushbutton
n @. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation.
Easy panel mounting from the front and simple lamp replacement.
without tools. Setting range: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages or undervoltages.
Manual resettingg and automaticallly resetting supported by one Relay H2A AC110 30S.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input ssuppported H2A AC110 30S.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
H2A AC110 30S Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=H2A AC110 30S&select=5