Name: CS1D Processcontrol CPU Unit.
Specifications: CPU section,
Equivalent to the CS1D-CPU67H;
Loop control section,
LCB05D Operation method:
Function block method,
Number of function blocks:
500 blocks max.
Minimum operation cycle:
100 ms PID control method:
PID with two degrees of freedom,
(with autotuning function);
Current consumption: 5 V system, 1 OMRON K8DT-TH1TD 24VAC/DC. 04A;
26 V system, --.
Standards: UC1, N, CE
K8DT-TH1TD 24VAC/DC
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Case color: Light gray.
Lighting method: LED; 24 VDC.
Display color symbol: R.O.G.W.
Large Rectangular-bodied Indicators OMRON K8DT-TH1TD 24VAC/DC.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting),
included in lineup . Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points OMRON K8DT-TH1TD 24VAC/DC.
SSR fault detection function for heater with broken line: detection function for single phase heater .
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrastName: Three-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Power supply voltage: 100 to 240 VAC.
Type: Temperature input.
Output relays: 1 relay.
Input types: Thermocouple or platinum resistance thermometer.
Setting units (setting range): Setting unit: 1°C or 1°F (0 to 999°C/°F).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design withh a width of just 22 .5 mm K8DT-TH1TD 24VAC/DC.
Rotary switches simplifies temperature settings.
Universal-input support for thermocouple or platinum,
resistance thermometer sensor input.
Change the output relay between normally open and,
normally closed operation. .
Alarm status identification with LED indicator K8DT-TH1TD 24VAC/DC.
Self-holding output.
Alarm output status can be retained even if the power,
supply is turned OFF.
K8DT-TH1TD 24VAC/DC Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=K8DT-TH1TD 24VAC/DC&select=5