Actuator: General purpose; Roller arm lever; AC.
Mounting: Diagonal side mounting.
Approved standards: UL CSA.
General-purpose Enclosed.
Switches with High Breaking.
Capacity and High Durability.
Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high,
breaking capacity OMRON CS1G-CPU44-V1.
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches
CS1G-CPU44-V1 DC models have also been added,
to the series.
Three mounting methods (side, base, and diagonal side),
and many types of actuator are available.
Terminals face the front when the cover is removed for,
easy connection OMRON CS1G-CPU44-V1.
Switches with ground terminals have CE marking.
Approved by UL, CSA, and CCC (Chinese standard) .
(Ask your OMRON representative for information on approved models.)Type: 1a1b welding terminal.
Shape: rectangle.
Type: small load.
Action: instantaneous action (auto recovery).
With light: LED with light.
Using voltage: DC24V.
Operation Department color: green.
20mm long, with 12 round series
High brightness all one side light OMRON CS1G-CPU44-V1.
Because it is round, so easy to punch .
Miniaturization, operation feel good. MITSUBISHI motor produced PLC connection cable.
Size: A, 3000mm; B, 1750mm.
Output use.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Output: SPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss . CS1G-CPU44-V1.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eeexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
CS1G-CPU44-V1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=CS1G-CPU44-V1&select=5