Model: DSR (67S).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular CPM1A-40CDT-A-V1 Price.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system
CPM1A-40CDT-A-V1
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system CPM1A-40CDT-A-V1 Price.
Can also correspond to the generator and the electric side / internal tributaries .
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident CPM1A-40CDT-A-V1 Price.
2 stage cross terminal stand with cover with convenient wiring . Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: --.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UUL Class 2 Output standardss OMRON CPM1A-40CDT-A-V1.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) OMRON CPM1A-40CDT-A-V1.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
CPM1A-40CDT-A-V1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=CPM1A-40CDT-A-V1&select=5