Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0 MITSUBISHI FR-HC2-30K. 1A.
External connection: 3 line /2 line type.
Sensor connector type (E-CON type)
FR-HC2-30K
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Servo motor series: medium inertia, small capacity MITSUBISHI FR-HC2-30K.
Rated output: 1.5kw.
Rated speed: 2000r/min.
Electromagnetic brake: incidental .
Power supply: 400V.
Stable driving of medium capacity and medium inertia type products.
Through the optimization of structural design, to achieve the minimum length of the industry.
High speed & high torque. Shorten the positioning time, achieve high-speed equipment.
Reducing the electric torque ripple MITSUBISHI FR-HC2-30K.
Through the combination of the optimal number of the motor and the slot number, the torque ripple is greatly reduced,
To further realize the smooth constant speed device .
Improve the environmental performance of HG-SR, HG-JR series of products using IP67. RS-232:1 channel, RS-422:1 channel.
BASIC program mode (A3MCPU corresponding): BASIC console interface to use.
Sequential program mode (program controller CPU correspondence): non sequential computer connection interface and use.
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc..
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second stteps .
Design PPLC peripheral hardware circuit FR-HC2-30K.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system compooseed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram FR-HC2-30K.
So far the system''s hardware electrical circuit has been determined.
FR-HC2-30K Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FR-HC2-30K&select=5