Input / output points: 4096 points.
Size side mode: small end mode.
SD memory card: available.
Q24DHCCPU-LS without OS.
C language controller is a long term stable supply, high reliability, high performance, flexible MELSEC on the implementation of the C language program revolutionary open platform.
Including pre installed VxWorks,
This C language controller can be used with various modules of the MELSEC-Q series,
Partner products and open source,
Client program assets, such as portfolio use to build a variety of systems
HA-LF22K1M
As can be used in all scenarios, can replace the computer, a new computer platform,
C MELSEC language controller stronger, simpler, higher performance, more flexible, in the future will also continue to continue to develop MITSUBISHI HA-LF22K1M.
Type of input: DC leakage.
Input points: 32 points.
Input voltage: DC12/24.
Input current: 3/7mA.
Output type: transistor drain type.
Output points: 32 points.
Common public end points: 32.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control MITSUBISHI HA-LF22K1M.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these sstandard electrrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal HA-LF22K1M.
So the standard telecommunication number, the conversiionn between the number of operations to use a variety of computing HA-LF22K1M.
This requires the resolution of the analog unit and the standard electrical signal.
HA-LF22K1M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HA-LF22K1M&select=5