Motor series: low inertia, medium power.
Rated output power: 11.0kw.
Rated speed: 1500r/min.
Whether to bring the brakes: with.
Shaft end: Standard (straight).
Voltage: 400V type.
Protection level: IP65 (IP67).
Features: low inertia from low speed to high speed, three modes can be selected, suitable for different application range MITSUBISHI R04ENCPU. As a standard port, 30KW or greater power is suitable for flange (type) installation and support foot mounting
R04ENCPU
Application example: injection molding machine, semiconductor manufacturing equipment, large conveyor machinery.
High resolution encoder 131072p/rev (17 bit).
The encoder with high resolution ensures excellent performance and stability at low speed MITSUBISHI R04ENCPU.
All motor dimensions are the same as before and all are compatible with the wiring . Function: CPU module (internal service power supply).
Input and output points: 80 points.
Power supply capacity (DC5V power): 1100mA.
Power supply capacity (DC24V service power supply): 600mA.
Input / output mode: DC input (drain / source) / transistor (drain) MITSUBISHI R04ENCPU.
Input points: 40 points.
Output points: 40 points.
The new expansion module is more convenient!
Pioneer products with advanced built-in functions and rich extensibility .
FX5U built-in analog, communication, high speed input and output,
By extending the board and adapter can be easily extended system.
In addition, through the high speed system bus,
Can maximize the role of the built-in intelligent functions of the expansion device.
AnS, QnAS bus connection, the reader to write program 2 channel connection.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.
The response time of PLC is the interval between the time of the change of the external output siignal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the usse oof the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on R04ENCPU R04ENCPU.
This phenomenon is called the I/O delay time effect.