MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 0.4kw.
Interface type: SSCNET type III fiber communication.
Special specification: suitable for direct drive servo motor.
Power specification: single phase AC200V.
Direct drive system suitable for high speed and high precision!
High speed operation can be realized by direct drive (2m/s), and the traditional mechanical transmission can not achieve such a high speed
R60ADI8
The full closed loop control can be realized by using the position feedback signal from the load side encoder, such as the linear encoder.
The use of a flexible linear servo motor drive components can make the system more compact structure R60ADI8.
The primary side of the linear servo motor (motor coil) is sliding along the secondary side (permanent magnet) of the motor,
So linear servo motor is especially suitable for large range of applications . In addition, linear servo motor can be connected in series,
Especially for large systems in two axes for high precision synchronous operation R60ADI8. MELSECNET/10, MELSECNET/H coaxial, input voltage: AC100-240V.8 slots .
No need to install power.
For QnA/A series.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Cenntralized output mode . MITSUBISHI R60ADI8.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation MITSUBISHI R60ADI8.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.