LK Automation Limited
Home >> Price >> OMRON >> 3G3FV-A4110 OMRON 3G3FV-A4110
Brand sort

3G3FV-A4110 OMRON 3G3FV-A4110

No PHOTO
Country: JAPAN
Name:
Model: 3G3FV-A4110
Market price: U.S.$ 0
(The following are the market open price not sales price!)
OMRON 3G3FV-A4110
Size: 48 x 48mm.
Body: terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: - OMRON 3G3FV-A4110.
Event input points: -.
Transfer output: transfer output (special terminal) 3G3FV-A4110
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance OMRON 3G3FV-A4110.
High resolution 5 bit display / can display 0 . 01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV OMRON 3G3FV-A4110.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultType: H5CX-A series .
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 .
External cconnections: Screw terminals 3G3FV-A4110.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Cable type: Standard Cables.

Tyype: Cable with Plug on One End (M12 Straight) 3G3FV-A4110.
Cable length: 2 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks.
3G3FV-A4110 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=3G3FV-A4110&select=5


...more relevant model market price >>>>