LK Automation Limited
Home >> Price >> MITSUBISHI >> FR-A540-18.5K-CH MITSUBISHI FR-A540-18.5K-CH
Brand sort

FR-A540-18.5K-CH MITSUBISHI FR-A540-18.5K-CH

No PHOTO
Country: JAPAN
Name:
Market price: U.S.$ 0
(The following are the market open price not sales price!)
MITSUBISHI FR-A540-18.5K-CH
Cable length: 30m.
For long distance connections between QCPU and GOT (above 13.2M) (need A9GT-QCNB).
Long distance connection between two GOT.
Applicable models: GT16, GT15, GT11, GT27, GT25. 4 axis, differential drive output type.
Control unit: pulse.
Location data: 10 data / axis.
Maximum pulse output: 4Mpps MITSUBISHI FR-A540-18.5K-CH.
40 pin connector.
Differential output.
Ideal solution for simple multi axis positioning FR-A540-18.5K-CH
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle.
To speed up the speed of positioning control to start processing.
Positioning module.
Open collector output.
Differential driver output MITSUBISHI FR-A540-18.5K-CH.
Based on the use of open collector outputs and differential drive output type 2 types .
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control.
(the command pulse of the open collector positioning module is highest 200kpps MITSUBISHI FR-A540-18.5K-CH. )
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card .
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown. Output points: 32 points.
Voltage: DC24V/AC240V, 2A/1 point, 5A/1 public end.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
38 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoidd valve can be known,,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 outtput, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points FR-A540-18 FR-A540-18.5K-CH.5K-CH.
FR-A540-18.5K-CH Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=FR-A540-18.5K-CH&select=5


...more relevant model market price >>>>
Related products