"Maximum control axis: 4 axis.
Connection mode with servo amplifier: SSCNET III /H connection type.
The maximum distance between the drive units: 100m.
Operation cycle: 0.88ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points.
Color detecting set: 4 set MITSUBISHI GT1575-VTBA.
Even the long distance wiring can be flexible.
The use of fiber optic cable, with high speed, high performance, high reliability of the servo system controller network
GT1575-VTBA
In addition to the traditional positioning control, but also to support speed / torque control and synchronous control.
Use simple movement module setup tool",
Can easily perform positioning settings, monitoring and debugging, etc MITSUBISHI GT1575-VTBA. .
In addition, the data can be collected and displayed synchronously with the motion controller.
SSCNET III /H connection to save the wiring, the maximum distance between the station up to 100m,
Absolute position system can be easily supported.
The upper limit limit switch, the lower limit switch and the near point block signal are input by the servo amplifier,
Thus greatly reducing wiring MITSUBISHI GT1575-VTBA.
In addition to positioning control and speed control, but also to perform synchronization control, cam control, torque control, touch pressure control, etc..
Positioning module (QD75MH) of the project and the sequence of the previous model is highly compatible with the old model,
The project can be easily applied to the simple motion module (QD77MS). "Output points: 24 points.
Voltage: AC100 ~ 240V.
OFF leakage current: 0.1mA.
Output type: bidirectional thyristor output.
Response time: 0.5Hz+1ms.
36 point terminal station.
With short circuit protection.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoidd valve can be kknown,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 outtput, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points GT1575-VTBA GT1575-VTBA.
GT1575-VTBA Operation manual/Instructions/Model selection sample download link: