Motor series: low inertia, low power.
Rated output power: 0.75kw.
Rated speed: 3000r/min.
Whether to bring the brakes: with.
Shaft end: key shaft (open slot).
Protection level: IP55 does not include the shaft part and the connector.
Features: low inertia is particularly suitable for high speed motor (6000 or 12000 RPM / min) of general industrial machinery MITSUBISHI .
Application example 1: drive belt drive, robot
Q172CPUN
Application example 2: assembly machine, sewing machine, X-Y working table.
Application example 3: food manufacturing machinery, semiconductor manufacturing equipment, knitting machine and embroidery machine.
High resolution encoder 131072p/rev (17 bit) MITSUBISHI .
The encoder with high resolution ensures excellent performance and stability at low speed .
All motor dimensions are the same as before and all are compatible with the wiring. Type of input: DC leakage.
Input points: 8 points.
Input voltage: DC24.
Input current: 7mA.
Output type: transistor drain type.
Output points: 8 points.
Common public end points: 8.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control MITSUBISHI .
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these sstandard electrical signnals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal MITSUBISHI Q172CPUN.
So the standard telecommunication number, the conversiionn between the number of operations to use a variety of computing MITSUBISHI Q172CPUN.
This requires the resolution of the analog unit and the standard electrical signal.
Q172CPUN Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=Q172CPUN&select=5