8 slots.
Power supply unit.
QnAS series unit installation.
High speed access.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point
A1SJ-56DR
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30% MITSUBISHI A1SJ-56DR.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program .
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage MITSUBISHI A1SJ-56DR.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action. Oil resistant cap for 5.7 inch screen.
Applicable models: GT15, GT11, GT10. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 2.2kw.
SLD converter rated current: 16.7A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
((rectifier sepparation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station A1SJ-56DR.
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same timme,, used in the control of the external machine A1SJ-56DR.
No external PID controller is used to control the external machine, so the system cost can be reduced.
A1SJ-56DR Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A1SJ-56DR&select=5