CC-Link interface module.
PLC FX can be used as the CC-LINK remote device station connection.
If using CC-LINK type FX2N-16CCL-M system master module,
So just PLC CC-LINK can build FX system. Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO.
Safe input points: 1 points (2 input).
Start input points: 1 GT15-A1SC50B Price.
Input type: P type (positive public end / positive public end input)
Safe output points: 1 points (3 output)
GT15-A1SC50B
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features.
Saving wiring by CC-link connection.
The wiring is not needed in particular to the condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces GT15-A1SC50B Price.
Visualization of installation status.
Can monitor the safe output, as well as the safety input and the internal state of the relay, in the safety circuit to facilitate the identification of the reasons for the start. Input and output points: 2048 points.
Input / output data points: 2048 points GT15-A1SC50B Price.
Program capacity: 30K.
Basic command processing speed (LD command): with 1 s coaxial data communication line function .
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage cappacity: it is a measure of hhow much the user application can store the number of indicators MITSUBISHI GT15-A1SC50B.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words MITSUBISHI GT15-A1SC50B. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
GT15-A1SC50B Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=GT15-A1SC50B&select=5