Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. Motor series: super low inertia, medium power.
Rated output power: 2.0kw.
Rated speed: 3000r/min.
Whether to bring the brakes: with.
Shaft end: Standard (straight).
Protection level: IP65 (IP67) E-GMJ-200CAB.
Features: ultra low inertia is suitable for high frequency operation.
Application example: ultra high frequency transmission machinery
E-GMJ-200CAB
High resolution encoder 131072p/rev (17 bit).
The encoder with high resolution ensures excellent performance and stability at low speed.
All motor dimensions are the same as before and all are compatible with the wiring E-GMJ-200CAB. MITSUBISHI inverter FR-F740 series .
Voltage level: three phase 400V.
Frequency converter capacity: 500KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor E-GMJ-200CAB.
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor .
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity. Output type: transistor output, drain type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0.1A.
External connection: 2 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Output type: transistor output, drain type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
RRated load voltage / currentt: DC12V/DC24V/0 MITSUBISHI E-GMJ-200CAB.1A.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0.3~1.5MM square.
Terminal block is 2 piece structure.
An input module shared by the coommon terminal of the positive and negative MITSUBISHI E-GMJ-200CAB.
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction.