Cable length: 1m.
Used to extend the USB port of the GOT to the control cabinet.
Applicable models: GT10, GT21. MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 3.5kw.
Interface type: SSCNET type III fiber communication.
Full closed loop control.
Power specification: three phase AC400V MR-J3BUS05M-C.
High precision and high response location control.
Full closed loop control can be realized by double feedback control method
MR-J3BUS05M-C
Dual feedback control can be performed between the servo motor encoder and the load side encoder.
MR-J3-B-RJ006 can be used in conjunction with a number of manufacturers of linear encoder,
Users can build the system according to their own accuracy requirements MR-J3BUS05M-C. ABS type linear encoder using serial interface,
No need to install the battery on the servo amplifier can easily build the absolute position detection system.
Flexible system configuration.
Can achieve higher load side positioning accuracy!Output type: transistor output, drain type.
Output points: 16 points MR-J3BUS05M-C.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0 . 1A.
External connection: 2 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 8A/1 public end.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
20 point terminal station.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoidd valve can be known,
A singlle coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 outtput, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI MR-J3BUS05M-C MITSUBISHI MR-J3BUS05M-C.
MR-J3BUS05M-C Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-J3BUS05M-C&select=5