Input points: 16 points.
Rated input voltage: AC100 ~ 120V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on
Q2ASHCPU-S1 MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 560kw.
SLD converter rated current: 1212A.
Structure and function: the rectification part is off type Q2ASHCPU-S1.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor .
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation.
Can reduce the power consumption in the stop. I/O control method: refresh mode or direct mode.
User program storage capacity: 8K step.
I/O points: 256 points.
Memory capacity: bytes 64K.
ANSCPU has been updated to ANSHCPU, and it has the following advantages.
16 bit dedicated microprocessor.
Large capacity battery backup memory RAM.
Extended I/O control capability.
Dedicated CC-Link instruction.
Capacity for extended comment storage.
PLC programming is a digital computing operation of the electronic system,
Designed for applications in industrial environments.
It uses programmable memory,
An instruction used tto perform logical operatioons, sequence control, timing, counting and arithmetic operations in its internal storage,
And through the digital, analog input and output, control of various types of machinery or production process MITSUBISHI Q2ASHCPU-S1.
Programmable controllleer and related equipment,
Should be easy to make the industrial control system to form a whole, easy to expand the principle design of its functions MITSUBISHI Q2ASHCPU-S1.
Q2ASHCPU-S1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=Q2ASHCPU-S1&select=5