Material: SUS303(Equivalent to SUS304).
Weight (g): Approx. 12.
Material indication: Blank.
A Wide Variety of Electrodes for Long Lasting.
Reliability.
Standard Electrodes are made of stainless steel (SUS 304) and,
can be used in applications for purified water.
SUS316 Electrodes can be used in applications where resistance,
to corrosion is required OMRON E2EM-X4C2 2M. Titanium and HAS Electrodes can be,
used in applications where resistance to acid is required
E2EM-X4C2 2M
For applications where long electrodes are required, a connection,
nut and two Lock Nuts can be used to extend the electrodes 1 m,
at a time. Receptacle box: G 1/2 Conduit OMRON E2EM-X4C2 2M.
Indicator: Without indicator.
Actuator: Top plunger, Standard.
Approved standards: UL, CSA .
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals OMRON E2EM-X4C2 2M.
Block mounting method also reduces downtime for maintenance .
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.) Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to chhange the key inssertion point E2EM-X4C2 2M.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk SSafety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames E2EM-X4C2 2M.
The plastic material makes the Slide Key suitable,
for lightweight doors.
E2EM-X4C2 2M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=E2EM-X4C2 2M&select=5