Release key type: Trapped key *1.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+3NC.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns E2G-M12KN08-WP-D2.
Standard gold-clad contacts enable use with ordinary loads,
and microloads
E2G-M12KN08-WP-D2
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas E2G-M12KN08-WP-D2.
IP67 degree of protection. Appearance: Shielded, M12.
Sensing distance: 2 mm .
Output configuration: DC 2-wire, (3)-(4) pin arrangement.
Model: Operation mode, NO.
Chip-immune Inductive.
Proximity Sensor.
Correct operation even with aluminum or iron chips sticking,
to the Sensor.
Only the sensing object is detected.
Pre-wired Smartclick Connector Models also available E2G-M12KN08-WP-D2. Size: M8(Stainless steel)(See note 2.); Double; Shielded.
Sensing distance: 2 mm .
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Sensing method: Diffuse reflective.
Appearance: Vertical.
Connection method: Pre-wired .
Sensing distance: 30 to 50 mm.
Model: PNP Open collector output type .
Both Red-light Models and Green,
light Models to Detect a Wide Variety,
of Colors. Product name: CJ1M CPU Units; Ethernet function.
Specifications: I/O capacity/Mountable Units Expansion Racks),
160 points/10 Units (No Expansion Rack); Program capacity,
5K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0.1 μs;
Ethernet function,YES.
Current consumption: 5v, 0.695A (Seenote 2.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displayinng the status of the Temperaature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV OMRON E2G-M12KN08-WP-D2.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs OMRON E2G-M12KN08-WP-D2.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
E2G-M12KN08-WP-D2 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2G-M12KN08-WP-D2&select=5