Output: SPDT.
Lighting: LED.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry OMRON E5EZ-C3ML AC100-240.
Detachable Switch.
The same contacts can be used for both standard loads and microloads
E5EZ-C3ML AC100-240
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Size: 48 x 48mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 3 points (common universal) OMRON E5EZ-C3ML AC100-240.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input .
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
Remote SP input: there.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points OMRON E5EZ-C3ML AC100-240.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility .
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5EZ-C3ML AC100-240.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee ddisplay PV/SV E5EZ-C3ML AC100-240.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
E5EZ-C3ML AC100-240 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E5EZ-C3ML AC100-240&select=5