LK Automation Limited
Home >> Price >> OMRON >> OMRON E6C3-CWZ3EH 300P/R 2M E6C3-CWZ3EH 300P/R 2M
Brand sort

OMRON E6C3-CWZ3EH 300P/R 2M E6C3-CWZ3EH 300P/R 2M

No PHOTO
Country: JAPAN
Name:
Market price: U.S.$ 0
(The following are the market open price not sales price!)
OMRON E6C3-CWZ3EH 300P/R 2M
Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: transfer output (special terminal) OMRON E6C3-CWZ3EH 300P/R 2M.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E6C3-CWZ3EH 300P/R 2M
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0 OMRON E6C3-CWZ3EH 300P/R 2M. 01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors .
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay) OMRON E6C3-CWZ3EH 300P/R 2M.
Setting the program settings that can perform flexible contact output .
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Name: AC Input Unit.
Rated input voltage: 200/240 VAC.
Refer to Safety Precautions for All Solid State Relays.
AC Input Unit Enabling AC Operation.
Connects to a maximum of two G3PA-VD Relays. Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 15W.
Output voltage: 15V.
Output current: 1A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W outpput terminals)
Support finnger touch protection to prevent electric shock E6C3-CWZ3EH 300P/R 2M.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhenn the fan is replaced by the customer E6C3-CWZ3EH 300P/R 2M. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)

E6C3-CWZ3EH 300P/R 2M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=E6C3-CWZ3EH 300P/R 2M&select=5


...more relevant model market price >>>>
Related products