Function name: single phase 200V.
Power: 0.2KW.
Maximum output voltage: three phase 200 ~ 240VAC (corresponding input voltage).
Rated voltage, frequency: single phase power supply 200 ~ 50/60Hz, 240V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show.
Standard configuration has RS485 interface, Modbus bus communication function.
3Hz provides more than 150% torque output.
2-15kHz carrier frequency, can achieve mute driver.
Equipped with simple energy saving function.
Compact size and uniform, and can be installed close to the side by side.
Signal output function for controlling external brake action.
Software setting operation mode, no need to connect the control line can be used for speed control.
Box protection class: metal, IP00.
Terminal size: M8.
Line diameter: 30 square mm.
Weight: 4.6kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Specification: three phase 400V OMRON 3G3JZ-AB002.
Power: 3.7KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V
3G3JZ-AB002
Cooling: forced air cooling.
Weight: 1.9kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ.
3G3MZ series inverter for the application of frequency control and development OMRON 3G3JZ-AB002.
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice OMRON 3G3JZ-AB002. Level: 3 phase 200V level.
Connecting resistance: 17 or more.
Internal resistance value: 120W, 20W.
In 3G3MX2 with the use of the braking resistor, can shorten the motor deceleration time OMRON V/F controlled converter.
Alarm output terminal of regenerative braking unit.
The temperature relay built-in resistance or braking resistance optional activation,
A circuit to cut off the main power supply of the frequency converter OMRON V/F controlled converter. Box protection class: plastic, IP00.
Terminal size: M5.
Line diameter: 8 square mm.
Weight: 1.4kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line OMRON V/F controlled converter.
Try to be close to the transducer for connectionn 3G3JZ-AB002. Specification: small.
Impact resistance: 120W.
Resistance to impact resistance: 180.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resisttor OMRON 3G3JZ-AB002.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed.