I/O slots: 2 slots.
Can you install the power module.
Outline dimension: 155*130.
A power module can be inserted, and the other one is not.
The choice of any type of substrate depends on the total DC5V current consumption and the power supply on the CPU main substrate.
Then you can choose a more economical expansion board.
Both ends of the main base plate of the CPU have an expansion interface, and can be used for extending the cable connection.
AnS, QnAS bus connection, the reader to write program 1 channel connection.Output type: transistor source.
Output points: 16 points.
Load voltage: DC12/24.
Load current: 0.8A.
Connection mode: terminal row.
Common public end points: 8.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF MITSUBISHI A1S52B-S1.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC
A1S52B-S1
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control MITSUBISHI A1S52B-S1.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three. Three remote components can be connected to the CC-LINK system.
Remote I/O: refers to the field components that require only ON/OFF control,
Such as digital I/O or pneumatic valve, etc..
In this type of communication can only be carried out in the bit data MITSUBISHI A1S52B-S1.
Remote components: the field components that require processing of register data,
For example analog I/O and counter, etc..
In this type of component, in addition to the bit data can be carried out in the register data communication MITSUBISHI Extended bottom plate.
Intelligent remote: this type of element refers to the actions that allow the master station or other station to access,
To collect data and control the local PLC station,
GOTS and programmer interface unit are of this type MITSUBISHI Extended bottom plate.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work MITSUBISHI Extended bottom plate.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or addresss number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next rround of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work MITSUBISHI A1S52B-S1 A1S52B-S1.