LK Automation Limited
Home >> Products >> MITSUBISHI >> Ans/QnAs series PLC >> Analog module >> A1S66ADA Analog input / output module Generally, a scanning process, the fault diagnosis time, MITSUBISHI A1S66ADA

A1S66ADA Analog input / output module Generally, a scanning process, the fault diagnosis time, MITSUBISHI A1S66ADA

Brand: MITSUBISHI
Name: Analog input / output module
Model: A1S66ADA
Input channel number: 4.
Output channel number: 2.
Occupy I/O points: 64.
A1S63ADA analog input / output combination components can be analog / digital / digital / analog conversion,
The input and output signals can be voltage or current,
Offset and gain can be set and stored.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is called the I/O delay time effect.

3 slots; requires 1 AnS series PLC power modules;
Used to install large AnS series PLC module.
Base plate of AnS series PLC.
QA1S series PLC 3 slot main substrate.
AnS series of modules can be installed. Cable type: twisted pair.
A1SJ71PT32-S3 and A1SJ71PT32-S3 are the main control module of MELSECNET/MINI-S3,
The main PLC in the network can control 64 remote I/O modules MITSUBISHI A1S66ADA.
The main control module carries on the high speed data communication to the remote module on the connection network A1S66ADA
Each PLCCPU can use a number of main control modules,
But up to no more than the maximum allowed by the main I/O CPU points.
A1SJ71PT32-S3 can be used in the cable system can also be used in twisted pair cable system;
A1SJ71T32-S3 can only be used in twisted pair cable network MITSUBISHI A1S66ADA.
The popularization and application of PLC programming has been developed rapidly in our country,
It has been widely used in all kinds of mechanical equipment and production process of electrical control devices,
All walks of life have emerged a large number of application of PLC transformation of the results of the equipment MITSUBISHI A1S66ADA.
Understand the working principle of PLC, have the ability to design, debug and maintain the PLC control system,
Has become the basic requirements of modern industry for electrical technicians and engineering students.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations MITSUBISHI Analog input / output module MITSUBISHI Analog input / output module.
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC MITSUBISHI Analog input / output module.
The characteristics of instruction table programming languaage is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-tto-one correspondence between the ladder diagram and the ladder diagram MITSUBISHI A1S66ADA A1S66ADA. Its characteristics are basically consistent with the ladder diagram language.


...More relevant models >>>>