Home >> Products >> MITSUBISHI >> Ans/QnAs series PLC >> Input module >> A1SX40 MITSUBISHI A1SX40 Input module

A1SX40 MITSUBISHI A1SX40 Input module

Brand: MITSUBISHI
Name: Input module
Model: A1SX40
Type of input: DC leakage.
Input points: 16 points.
Input voltage: 12/DC24.
Input current: 3/7.
Connection mode: terminal row
Common common point: 16.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations.
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming language is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-to-one correspondence between the ladder diagram and the ladder diagram. Its characteristics are basically consistent with the ladder diagram language.

I/O slots: 5 slots.
Can you install the power module.
Outline dimension: 260*130.
There are two types of extended floor,
A power module can be inserted, and the other one is not.
The choice of any type of substrate depends on the total DC5V current consumption and the power supply on the CPU main substrate MITSUBISHI A1SX40.
If the total demand is less than the power output, no additional power supply,
Then you can choose a more economical expansion board A1SX40
Both ends of the main base plate of the CPU have an expansion interface, and can be used for extending the cable connection. Available network: Profibus-DP.
Function: Master station.
The A1SJ71PB96F and A1SJ71PB92D modules allow a PLC ANS to connect to the Profibus system,
Meet the CE standard, using SWOIX/ProfiMap special programming software MITSUBISHI A1SX40.
A1SJ71PB96F compatible with Profibus-FMS, as a master or client;
A1SJ71PB92D compatible with Profibus-DP, can be used as a master to control the remote Profibus-DP I/O. Output type: relay.
Output points: 8 points.
Load voltage: AC240/DC24.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 1 MITSUBISHI A1SX40.
Structured text language is a programming language that describes a program with a structured description of the text.
It is a programming language similar to a high level language. In large and medium
Structured text is often used to describe the relationship between the various variables in the control system based on the PLC system MITSUBISHI Input module.
Mainly used for other programming languages more difficult to achieve the user program MITSUBISHI Input module.
The structured text programming language uses the computer description method to describe the various kinds of relations between the various variables in the system,
Complete the required function or operation.
Most PLC manufacturers use structured text programming language similar to BASIC language, PASCAL language or C language and other advanced languages,
But in order to be convenient, the expression methods of the statement and the types of statements are simplified MITSUBISHI Input module A1SX40.
Structured text programming language features: the use of high-level language programming, you can complete the complex control operations,
Needd to have a certain level of computer knowledge and programming skills,
Higher requirements for engineering designers MITSUBISHI A1SX40. Poor visibility and operability.