LK Automation Limited
Home >> Products >> MITSUBISHI >> CC-Link module >> Other CC-Link modules >> CL1XY2-DT1D5S MITSUBISHI CL1XY2-DT1D5S

CL1XY2-DT1D5S MITSUBISHI CL1XY2-DT1D5S

Brand: MITSUBISHI
Name: Cable type input and output module
Model: CL1XY2-DT1D5S
Input type: DC input, positive common end.
Input points: 1 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
Output form: transistor output, leakage type.
Output points: 1 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.1A.
External connection: 3 line /2 line type.
Cable type.
Minimum size of industry.
Can be like a cable, placed in the online slot.
The communication cable and the external equipment connecting cable is a type, and the wiring is simple.
Communication side, input and output side with cable (50cm).

Voltage input range: due to different connection models, the maximum DC28.8V.
External connection mode: module power supply: Terminal 3 pin (M3 screw), communication line / module power supply unit.
When power supply from the external power supply (customer owned) to the CC-LINK/LT system, the whole system can be stable power supply MITSUBISHI CL1XY2-DT1D5S. Pulse input: DC input.
Default input: DC input CL1XY2-DT1D5S
Count range: 0~16777215.
Number of stations: 4 stops.
Station type: remote equipment station.
Configuration of master / local station,
In addition to the other site network with different CC-Link in addition to the main station and the remote station configuration can also be the main station and the local station configuration MITSUBISHI CL1XY2-DT1D5S.
A local PLC can communicate with the master station PLC and other remote workstations. Input type: DC input, positive public end / negative public end.
Input points: 8 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC12V/AC240V/2A MITSUBISHI CL1XY2-DT1D5S.
External connection: 2 line /2 line type.
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. Input type: DC input, positive common end MITSUBISHI Cable type input and output module.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA MITSUBISHI Cable type input and output module.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.5A.
External connection: 3 line /2 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup MITSUBISHI Cable type input and output module.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Input type: AC input.
Input points: 8 points.
Enter the response time: 20ms the following.
Rated input voltage / current: AC100V/7mA.

External connection: 2 wire CL1XY2-DT1D5S.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool MITSUBISHI CL1XY2-DT1D5S.