LK Automation Limited
Home >> Products >> MITSUBISHI >> CC-Link module >> Other CC-Link modules >> CL2Y16-TP1M1V MIL connector type output module MITSUBISHI CL2Y16-TP1M1V Rated load voltage / current: DC12V/DC24V/01A 

CL2Y16-TP1M1V MIL connector type output module MITSUBISHI CL2Y16-TP1M1V Rated load voltage / current: DC12V/DC24V/01A 

Brand: MITSUBISHI
Name: MIL connector type output module
Model: CL2Y16-TP1M1V
Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector.
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space.

Support Ver.2 CC-LINK. "Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.25mA.
Output protection function MITSUBISHI CL2Y16-TP1M1V.
Rated load voltage / current: DC24V/0.5A.
External connection: /2 line 2~4 line type CL2Y16-TP1M1V
Waterproof connector type.
Strong waterproof type of IP67 protection grade.
No need to stop the system can be replaced module.
Without the use of tools can be a simple connection, save time.
Terminal resistor built-in.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong MITSUBISHI CL2Y16-TP1M1V.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness MITSUBISHI CL2Y16-TP1M1V.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. Input type: DC input, positive / negative public end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA MITSUBISHI MIL connector type output module.
Output form: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No MITSUBISHI MIL connector type output module.
Rated load voltage / current: DC24V/AC240V/2A.
External connection: 3 line /2 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool MITSUBISHI MIL connector type output module. Input type: DC input, positive public end / negative public end.
Input points: 32 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 1 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulatiion debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program MITSUBISHI CL2Y16-TP1M1V CL2Y16-TP1M1V.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.


...More relevant models >>>>