LK Automation Limited
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT2-AD04 OMRON DRT2-AD04 Analog I/O Terminals

DRT2-AD04 OMRON DRT2-AD04 Analog I/O Terminals

Brand: OMRON
Name: Analog I/O Terminals
Model: DRT2-AD04
Classification: Analog input.
I/O points: 4 inputs (Resolution: 6, 000).
Performs Calculations on Analog Values within the Slave Itself.
Also Provides High Resolution at 1/30,000 (Full Scale) and,
Support for a Wide Variety of Data Sampling.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
Sampling data can be analyzed internally to provide a low-cost scheduler function.
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative,
calculation function.
Two I/O points can be allocated to any two of the following values: analog,
input, peak/bottom, top, valley, or rate-of-change. Values without an,
allocated I/O point can be read with message communications.

Short/disconnection detection: Not supported.
Specifications: Inputs, NPN (+ common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring OMRON DRT2-AD04.
Screw-less structure eliminates tightening work DRT2-AD04
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. I/O classification: Output.
Internal I/O circuit common: PNP (+ common).
I/O points: 32.
I/O connection method: MIL connector.
Rated voltage for communications power supply: 24 VDC.
Rated voltage for I/O power supply: 24 VDC OMRON DRT2-AD04.
Applicable relay: G3DZ-2R6PL.
Subminiature 32-point Remote Terminal with Connectors.
Compact dimensions: 35 × 60 × 80 (W × D × H).
Long-distance and high-speed communications modes available.
Downsizing enabled with 32-point MIL connector for I/O connection. Specifications: Inputs;
NPN (+ common);
16 points.
I/O connections: MIL connector(Connector with 10-cm cable) OMRON DRT2-AD04.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces OMRON Analog I/O Terminals.
35 x 60 x 80 mm (W x D x H). Analog I/O terminal with screw terminal,
block for EtherCAT communicaitons OMRON Analog I/O Terminals.
The input/output range can be easily,
changed by the setting with the switch.
Detachable screw terminal block,
facilitates the maintenance.
Moving average calculation function.
Settings within the range of 100μs-64ms.
(For input only.)
Disconnection detection function.
(For input only and for usage with,
1-5V or 4-20mA ranges OMRON Analog I/O Terminals. )
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.Specifications: Inputs; PNP (- common); 16 inputs.
I/O connections: Sensor connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage:
Supplied from the communications connector.
Includes Sensor Connector That Conforms to,
Industry Standards And Can Be Used to Connect.
Senssors with Pre-wired Cables without Using,
Special Tools DRT2-AD04.
Equipped with the standard Smart Slave,
functions that provide powerful.
preventative maintenance and,
troubleshooting capabilities.
Digital I/O Terminal compatible with,,
industry-standard sensor connectors OMRON DRT2-AD04.
Connect sensors easily without special tools.
Reduce time required for wiring.
Load short-circuit detection.


...More relevant models >>>>