LK Automation Limited
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT2-MD16CL-1 OMRON Environment-resistive Terminals with Transistors DRT2-MD16CL-1

DRT2-MD16CL-1 OMRON Environment-resistive Terminals with Transistors DRT2-MD16CL-1

Brand: OMRON
Name: Environment-resistive Terminals with Transistors
Model: DRT2-MD16CL-1
Specifications: I/O, PNP (input: - common, output: + common), 8 inputs/8 outputs.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
Common Smart Slave functionality provides strong support for equipment,
operation status monitoring and effective maintenance.
High degree of environmental resistance with dust-proof and drip-proof,
construction. (IP67)
Models with one connector for two outputs are available to make easier,
connection with hydraulic valve devices.
(Models with 16 outputs and models with 16 mixed I/O)

Unit type: 10 I/O points 6 inputs; 4 outputs, Connector.
Input: 6 points: 24 VDC.
Output: 4 points: transistor (sourcing).
Clock: Yes.
Slaves with the Complex Functionality Needed,
for Distributed Blocks.
Programmable Slaves combine devices, such as sensors and actuators,
into one functional unit that is treated as a DeviceNet slave OMRON DRT2-MD16CL-1.
Programmable Slaves greatly facilitate device distribution,
and functional organization DRT2-MD16CL-1
They help standardize programming between units and reduce the amount of,
programming required at the master.
I/O and operational checks can be performed for each functional unit,
rather than waiting.
for final system assembly, as with conventional distributed I/O systems OMRON DRT2-MD16CL-1. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON DRT2-MD16CL-1.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Digital I/O.
Internal I/O circuit common: PNP (+ common) OMRON Environment-resistive Terminals with Transistors .
I/O points: 16.
I/O connection method: M3 terminal block.
Models with 3-tier Terminals (16 Points),
Added to the Remote I/O Terminal Series OMRON Environment-resistive Terminals with Transistors .
Six Models are Available Depending on the,
NPN or PNP Configuration, Input Points,
I/O Points, or Output Points.
Incorporates easy-to-wire terminals each,
connecting to a single wire.
Reduces designing and wiring effort OMRON Environment-resistive Terminals with Transistors .
Incorporates a removable circuit block of cassette construction. Input/Output: Inputs.
Internal I/O circuit common: PNP (– common).
I/O points: 8 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip-proof,
coonstruction (IP67) enables direct on-site,
mounting DRT2-MD16CL-1.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (88-point models) OMRON DRT2-MD16CL-1.
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration.


...More relevant models >>>>