Specifications: Inputs; NPN (+ common); 16 inputs.
I/O connections: Sensor connector.
Supplied from the communications connector.
Supplied from the communications connector.
Industry Standards And Can Be Used to Connect.
Special Tools.
functions that provide powerful.
troubleshooting capabilities.
industry-standard sensor connectors.
Connect sensors easily without special tools.
Reduce time required for wiring.
Load short-circuit detection.
Short/disconnection detection: Supported.
Specifications: Outputs, NPN (- common), 32 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring OMRON DRT2-ID16S.
Screw-less structure eliminates tightening work
DRT2-ID16S
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Specifications: Inputs, NPN (+ common), 8 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC OMRON DRT2-ID16S.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including.
Economical Input, Output, and Mixed I/O Models.
Common Smart Slave functionality provides strong support for equipment,
operation status monitoring and effective maintenance.
High degree of environmental resistance with dust-proof and drip-proof,
construction. (IP67)
Models with one connector for two outputs are available to make easier,
connection with hydraulic valve devices OMRON DRT2-ID16S.
(Models with 16 outputs and models with 16 mixed I/O)Input capacity: 16 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min.
(between each input terminal and the V terminal)
OFF voltage: 5 VDC max OMRON e-CON Connector Terminals.
(between each input terminal and the V terminal)
OFF current: 1.0 mA max.
Input current: 6 OMRON e-CON Connector Terminals. 0 mA max./input (at 24-VDC);
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms (Default setting: 1 ms).
Number of circuits per common: 16 inputs/common.
Input indicators: LED display (yellow) OMRON e-CON Connector Terminals.
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion uniit per one I/O terminal unit DRT2-ID16S. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswitch and with tool software OMRON DRT2-ID16S.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.