Specifications: Outputs; NPN (- common); 16 points.
I/O connections: M3 Screw terminals.
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
of the control system.
on the communications power supply.
and equipment operating information.
Expansion via Expansion I/O Units.
maintenance is easier.
Name: Two-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; NPN.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON DRT2-OD16.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site
DRT2-OD16
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Digital output.
Internal I/O circuit common: NPN (- common).
I/O points: 16.
I/O connection method: M3 terminal block OMRON DRT2-OD16.
Models with 3-tier Terminals (16 Points),
Added to the Remote I/O Terminal Series.
Six Models are Available Depending on the,
NPN or PNP Configuration, Input Points,
I/O Points, or Output Points.
Incorporates easy-to-wire terminals each,
connecting to a single wire.
Reduces designing and wiring effort.
Incorporates a removable circuit block of cassette construction OMRON DRT2-OD16. Name: Slice I/O Units; Digital I/O Units.
Specifications: 8 inputs PNP.
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON Transistor Remote I/O Terminals.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON Transistor Remote I/O Terminals.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Internal I/O common: PNP.
I/O indicators: LED display (yellow).
Unit power supply current consumption: 90 mA max OMRON Transistor Remote I/O Terminals.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max.
Expansion functions: No.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multiple contacts DRT2-OD16.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,
switch and with tool software OMRON DRT2-OD16.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.